Działamy 24/7 - zadzwoń i uzyskaj ekspresowe wsparcie. Realizujemy naprawy w ciągu 1 dnia!
 Naprawa automatyki 24/7
Pomoc 24/7
Działamy 24/7 - zadzwoń i uzyskaj ekspresowe wsparcie. Realizujemy naprawy w ciągu 1 dnia.
Napisz do nas

Naprawa Baumüller

Serwis urządzeń Baumüller

Wróć na stronę naprawy

Lista błędów

Kod błędu Nazwa
1 BASS communication time monitoring
2 USS communication time monitoring
3 Cyclic data time monitoring
4 Demand data time monitoring
5 Incompatible software
6 Invalid boot source entry
7 Program branching error
8 Drive blocked
9 Incremental encoder 1, scaling error
10 EEPROM-to RAM copy error
11 Damaged boot data record header
12 Boot data record checksum error
13 Damaged primary data header
14 EEPROM too small
15 Error on data record save
16 Ambiguous converter type BKD/BKF (1-Q/4-Q)
17 Error ext. analog - digital converter
18 Unknown field power unit identifier
19 Field connection error (AC)
20 Armature power unit connection error (AC)
21 CCW rotating field at armature power unit
22 Phase failure at armature power unit
23 Microprocessor error 1
24 Microprocessor error 2
25 Microprocessor error 3
26 Microprocessor error 4
27 Microprocessor error 5
28 Microprocessor error 6
29 Microprocessor error 7
30 External watchdog tripped
31 Internal watchdog tripped
32 RAM test error
33 Parameter conflict (P 071 / P 073)
34 Repeated negative actual armature current
35 No synchronisation
36 Firing pulse interval differs from specified value
37 Armature circuit open (a = aG and lA < 10 % of setpoint)
38 Mains frequency < 45 Hz
39 Mains frequency > 65 Hz
40 Field current monitoring (actual field current < 50 % field current setpoint)
41 P 072 out of range
42 P 213 / P 215 parameter conflict
43 Shortcircuit/overload at a digital output
44 Overspeed (n > P 501)
45 Tachogenerator/encoder failure or armature circuit open (time to trip 12 scan cycles / 40 ms at 50 Hz)
46 Tachogenerator/encoder polarity reversed (time to trip 12 scan cycles / 40 ms at 50 Hz)
47 Speed range error (P 257)
48 Torque change time exceeded (> 100 scans)
49 Unknown armature power unit identification (current)
50 Data record selection error (digital input functions 1-6)
51 Input current < 3.3 mA at 4 mA to 20 mA
52 Mains undervoltage P 010 < 0.8 x P 070
53 Overcurrent TD1 (lA > 2x P 072)
54 Overcurrent TD2 (lA > 2x P 072)
55 Zero-current detector defective
56 Offset error armature current detector > 50 mV
57 Ambiguous data record change source
58 EEPROM empty
59 Parameter error in data record 1 (write error/value)
60 Parameter error in data record 2 (write error/value)
61 Parameter error in data record 3 (write error/value)
62 Parameter error in data record 4 (write error/value)
63 Parameter error in data record 5 (write error/value)
64 Parameter error in data record 6 (write error/value)
65 Error in ROM data record (no. 7)
66 Primary data parameter error
67 Armature power unit identification differs from EEPROM value
68 Data record change: Data record does not exist
69 Field power unit differs from EEPROM value
70 Option board does not respond
71 Illegal value in P 072 / P 074 in data record 1
72 Illegal value in P 072 / P 074 in data record 2
73 Illegal value in P 072 / P 074 in data record 3
74 Illegal value in P 072 / P 074 in data record 4
75 Illegal value in P 072 / P 074 in data record 5
76 Illegal value in P 072 / P 074 in data record 6
77 Illegal value in P 079 in data record 1
78 Illegal value in P 079 in data record 2
79 Illegal value in P 079 in data record 3
80 Illegal value in P 079 in data record 4
81 Illegal value in P 079 in data record 5
82 Illegal value in P 079 in data record 6
83 EEPROM write time exceeded
84 Primary data checksum error
85 Checksum error in data record 1
86 Checksum error in data record 2
87 Checksum error in data record 3
88 Checksum error in data record 4
89 Checksum error in data record 5
90 Checksum error in data record 6
91 Undefined field bus card status
92 Field bus error
93 Field bus setpoint/actual value configuration error
94 P 657 / P 658 parameter conflict
95 Motor reached switch off temperature channel 1 ( motor temperature > P543 )
96 Motor reached switch off temperature channel 1 ( motor temperature > P546 )
97 Disconnection of motor temperature sensor channel 1 (X8:1 and X8:2 board 3.0043)
98 Disconnection of motor temperature sensor channel 2 (X8:4 and X8:5 board 3.0043)
99 Short circuit of motor temperature sensor channel 1 (X8:1 and X8:2 board 3.0043)
100 Short circuit of motor temperature sensor channel 2 (X8:4 and X8:5 board 3.0043)
101 Cable break temperature sensor power unit
102 Short circuit temperature sensor power unit
103 Power unit limit temperature exceeded (P112 = 1)
104 Error reaction freely definable error (P730 ^ 0)
Zapytaj o naprawę automatyki przemysłowej